Abstract
This article describes a quality improvement project to reduce the number of patients with diabetes who have poor glycemic control in a large tertiary care endocrinology clinic. The project used the Lean Six Sigma Define-Measure-Analyze-Improve-Control process improvement methodology to develop clinic workflow processes for obtaining A1C measurements in a timely manner to facilitate interventions to improve glycemic control. The percentage of patients with poorly controlled diabetes (A1C >9.0% or missing value in the past 12 months) significantly improved from 26.4% at baseline to 16% (P <0.001), and the proportion of patients with an A1C test within 3–6 months of an appointment improved from 76 to 92%.
- © 2020 by the American Diabetes Association
Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered. More information is available at https://www.diabetesjournals.org/content/license.